CLEARVIEW Hydrogen Peroxide Vapor Analyzer System

氢Peroxide Vapor Analyzer System

Turnkey solution for the measurement of hydrogen peroxide and water (H2O2and H2O) concentrations in vapor phase

OurGUIDED WAVE™ CLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemis a simple turnkey solution for the measurement of hydrogen peroxide and water (H2O2and H2O) concentrations in vapor phase. These are both measured together because they are codependent. The analyzer operates in real time, which takes the guesswork out of determining the H2O2and H2O concentrations during cycle development and throughout the actual sterilization cycle. The user gains continuous, accurate data for documentation and validation.

WHY IS IT IMPORTANT TO MEASURE hydrogen peroxide and water (H2O2and H2O) concentrations in vapor phase?

Measuring hydrogen peroxide (H2O2) and water (H2O) concentrations in vapor phase is important for several reasons:

  • Occupational safety:H2O2 is a strong oxidizing agent that can be hazardous to human health if inhaled or ingested in high concentrations. Measuring the concentration of H2O2 in vapor phase can help ensure that occupational exposure limits are not exceeded and workers are not exposed to unsafe levels.
  • Process control:H2O2 and water vapor concentrations are important parameters in several industrial processes, including sterilization, disinfection, and semiconductor manufacturing. Measuring these concentrations can help ensure process efficiency, consistency, and product quality.
  • Regulatory compliance:Several industries, including healthcare and pharmaceuticals, have regulations and guidelines for H2O2 and water vapor concentrations in the air. Measuring these concentrations is necessary to ensure compliance with regulations and to protect public health.
  • Environmental monitoring:H2O2 and water vapor can be emitted from industrial processes and can impact the environment. Measuring these concentrations can help identify potential environmental impacts and ensure compliance with environmental regulations.

APPLICATIONS

Here are some applications that use theGUIDED WAVE CLEARVIEW Hydrogen Peroxide Vapor Analyzer System:

  • Sterilization process validation and optimization
  • Cleanroom and isolator environmental monitoring
  • Microbial contamination control
  • Bioreactor and fermenter monitoring
  • Quality control in pharmaceutical manufacturing
  • Research and development in biotechnology and life sciences
  • Medical device manufacturing
  • Food and beverage processing
  • Environmental monitoring and testing






Measuring H2O2and H2O Under Ambient or Vacuum Conditions – Ideal
for Low Pressure Monitoring

Process Insights_Guided Wave Hydrogen Peroxide Vapor Analyzer HPVA Photometer Systems

Got a question? Not sure what you need? Just complete theApplication Questionnaire. We’re here to help.

GET A QUOTE TODAY | SERVICE | SALES | TRAINING

Americas +1.916.638.4944
EMEA +49 69 20436910
China/APAC +86 400 086 0106

info@process-insights.com

info@emea.process-insights.com

support.rc@process-insights.com

INDUSTRIES

TheGUIDED WAVE CLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemis primarily used in:

  • Pharmaceutical manufacturing industry
  • Sterile production areas, such as cleanrooms and isolators
  • Used in other industries where hydrogen peroxide is used for sterilization, such as medical device manufacturing, biotechnology, and research laboratories.

The system is designed to measure the concentration of hydrogen peroxide vapor in real-time, providing critical information for the decontamination process. Hydrogen peroxide vapor is commonly used as a sterilization agent in these environments to ensure the elimination of microbial contamination. It’s a non-invasive and non-destructive tool that provides rapid, accurate, and reliable analysis of hydrogen peroxide vapor concentration. It helps to ensure that the decontamination process is effective and that the sterile environment is maintained.

Easy Operation and Control

TheGUIDED WAVE CLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemis controlled via its touch screen or remotely via Ethernet (Modbus TCP/IP). All of the analytical calculations are encoded in the software. The complete system consists of a CLEARVIEW HVP Analyzer, one or two G-SST probes, and a pair of fiber optic cables for each probe. The analyzer is pre-calibrated at the factory. No programming is required by the user. Start-up requires powering the analyzer, connecting the probe or probes via the fiber optic cables, taking a ZERO reading in the dehumidified isolator and the H2O2and H2O concentration measurements may begin.

Performance Validation

When performance validation is required theG-SST probehas a built-in validation filter (optional) made of polymeric material. This makes validation of performance easy, at any time. The filter has unique spectral characteristics at the wavelengths used to measure H2O2and H2O. It was chosen because of its insensitivity to moisture and temperature conditions. To make a validation measurement, the validation filter is temporarily moved into the light path and the optical characteristics of the system are checked.

To Top

ANALYZER OPTIONAL ENCLOSURES

Typically for medical, pharmaceutical and food industries, theGUIDED WAVE CLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemmay be housed in a stainless-steel enclosure. Other enclosure options are available, such as, painted carbon steel, explosion-proof or purged depending on area classification requirements.

USER PROGRAMMABLE FEATURES

• Password protection for configuration changes
• Sampling time: 1 second minimum. User settable
• Reporting units: mg/L or ppm-V

To Top

ANALYZER SYSTEM ACCESSORIES AND OPTIONS

  • 2nd channel for additional independent sampling point
  • Custom length fiber cables
  • KF or Tri-clover® flanged fiber feed throughs and dual fiber feed throughs
  • Annual factory calibration service available
  • Universal power supply (110-240 VAC converter to 24 VDC)
  • Custom calibration for elevated temperature on request

FIBER CABLE

• 500 µm Ultra Low-OH fiber with stainless steel SMA-905 connectors
• Kevlar® protected or armored cables available

THE SMART CHOICE FOR RELIABLE MEASUREMENT

OurGUIDED WAVE CLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemdelivers accurate, real time H2O2and H2O measurement results. Its long-term stability and no maintenance requirements make it a cost effective, smart choice to help optimize production and ensure product quality ultimately enhancing profitability. As an ISO 9001 certified company, we maintain expert technical support and responsive global service for the lifetime of the system.

GUIDED WAVE CLEARVIEW Hydrogen Peroxide Vapor Analyzer System

Channels

1 or 2

Enclosure Options

Stainless Steel: 16 in x 12 in x 6 in (41 cm x 30 cm x 15 cm); Painted Carbon Steel: 14 in x 12 in x 6 in (36 cm x 30 cm x 15 cm)

Response Time

1 second, minimum. User settable

H2 O2 Vapor Measurement Range

0.1 – 50.0 mg/L [71.2 – 35,600 ppm V/V]

H2 O2 Measurement Accuracy

± 0.1 mg/L

H2 O Vapor Measurement

1.0 mg/L – to condensation [>1345 ppm V/V]

H2 O Measurement Accuracy*

“1.0 mg/L *
Relative to concentration at time of reference”

Ambient Temperature

10 °C – 45 °C

Optimal Ambient Temperature Stability

< ±2 °C

Relative Humidity

0– 90% non-condensing


FAQs

Q: What needs to change or be configured on theCLEARVIEW Hydrogen Peroxide Vapor Analyzer System在安装和测试一个新的50厘米G-SST调查from the currently installed shorter 28cm optical path G-SST probe?

A:Since the new 50 cm probe and the currently installed older style (28 cm) probe use the same sanitary flange size and are about the same physical length, you need to follow the setup changes as described in Appendix B of theCLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemmanual to correct for the increase in optical pathlength. See Figure 1 below.

Figure 1: Appendix B ClearView db Menu Tree

Follow these steps when upgrading from 28.3 cm path to 50cm G-SST Vapor probes, make this change in the analyzer Answers Adjust Screen.

  • See Slope Value of 0.0353 (1/28.3cm). Change that to 0.02
  • Select SAVE after the change
  • Perform this for EACH answer (H2O) and H202)

What needs to change is a slope value in computing the answer for each component. The slope value is a scaling function of 1/pathlength in cm.

Go to the Answer Adjust Page and see the location where the current slope exists. For 28.3cm path probe it should be 0.0353. Change that value to 0.02 that corresponds to 1/50.

Select SAVE then exit.

You are now ready to operate with the new upgraded VHP GSST Vapor Probes.

Q: Is there a way to easily test the replacement 50cm probe for correct operation once installed on theCLEARVIEW Hydrogen Peroxide Vapor Analyzer System?(other than running a full cycle and just monitoring)

A: To easily test the new 50 cm G-SST probe once connected to theCLEARVIEW Hydrogen Peroxide Vapor Analyzer Systemnote the water vapor at ambient. Then put the chamber in a vacuum mode. The moisture level should drop as the chamber is evacuated.

Alternatively, the 50cm vapor G-SST probe can be relocated into a humidity chamber, then inject a certain level of moisture and read once the humidity has stabilized.

To Top

OUR NIR-UV-VIS PROCESS & LAB ANALYZERS

NIR-O™

GUIDED WAVE™ Process Analyzer Spectrometer
Process Insights_guided wave- NIR-O_process analyzer

LAB NIR-O™

GUIDED WAVE™ Full Spectrum NIR Laboratory Analyzer Spectrometer
Process Insights_guided wave - Lab-NIRO-1

Stability Monitoring System

导波™紫外分析仪分光计
Process Insights_guided wave- NIRO_web

508 UV-VIS™

导波™紫外分析仪分光计
Process Insights_guided wave-M508-analyzer Closed-Door

LAB M508plus™ Benchtop

GUIDED WAVE™ Benchtop or LAB UV-VIS Analyzer Spectrometer
Process Insights_Guided Wave_Model 508plus benchtop

ClearView db™

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometers
Process Insights_Guided Wave ClearView-db-enclosures-400x135

APHA Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer System
Process Insights_Guided Wave ClearView-db-enclosures-400x135

ASTM Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer System
Process Insights_Guided Wave ClearView-db-enclosures-400x135

Saybolt Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer
Process Insights_Guided Wave ClearView-db-enclosures-400x135

Turbidity Color Analyzer

GUIDED WAVE™ VIS-NIR Dual-Beam Analyzer Photometer

Probes & Flow Cells / Fiber & Accessories

GUIDED WAVE™ Accessories for NIR-UV-VIS
Process Insights_Probes & Flow Cells
To Top

Questions? We’re here to help.

Baidu